CHTYB - ULTRAJET, ULTRAJET ALL-WAY, ES520
- MSDS: CHTYB
- Manufacturer: CHEMTRONICS INC
- Product Name: ULTRAJET, ULTRAJET ALL-WAY, ES520
- National Stock Number: 6830-00N089323
Product Identification
Product ID:ULTRAJET, ULTRAJET ALL-WAY, ES520
MSDS Date:10/06/1997
FSC:6830
NIIN:00N089323
Status Code:A
MSDS Number: CHTYB
Responsible Party
KENNESAW, GA 30152
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 800-832-4401
Cage: 2M589
Contractor
Telephone: 770-424-4888/800-645-5244
Cage: 2M589
Ingredients
1,1,1,2-TETRAFLUOROETHANE; (TETRAFLUOROETHANE)
CAS: 811-97-2
RTECS: KI8842500
Fraction By Weight: 100%
OSHA PEL N/K
ACGIH TLV: N/K
0.0 LB/0 GM.
RTECS: 9999999VO
INERT MATL (E.G., DRY SAND/EARTH), THEN PLACE IN
RTECS: 9999999ZZ
REPORTING SPILLS OF THIS MATL THAT COULD REACH ANY
RTECS: 9999999ZZ
1-800-424-8802. FOR MORE
RTECS: 9999999ZZ
LOCAL EXHAUST VENT MAY BE NEC TO CONTROL ANY AIR
RTECS: 9999999ZZ
OR WHEN LARGE AMOUNTS ARE RELEASED.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:CONTACT WITH LIQUID IS IRRITATING
AND MAY CAUSE FROSTBITE. SKIN:CONTACT CAUSES FROSTBITE; PROLONGED
CONTACT CAN CAUSE IRRITATION. INGESTION:UNLIKELY DUE TO VOLATILE
NATURE OF PRODUCT. CONTACT WIT H LIQUID MAY CAUSE FROSTBITE TO
MOUTH AND THROAT TISSUES. INHALATION:HARMFUL IF INHALED. HIGH (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CONCENTRATIONS OF VAPORS IN IMMEDIATE
AREA CAN DISPLACE OXYGEN AND CAN CAUSE DIZZINESS, UNCONSCIOUSNESS
AND EVEN DEATH WITH LONGER EXPOSURE. KEEP PEOPLE AWAY FROM SUCH
VAPORS WITHOUT NIOSH AP PROVED SELF-CONTAINED BREATHING APPARATUS.
Medical Cond Aggravated by Exposure:HEART, LUNG, SKIN, EYE.
First Aid
First Aid:EYES:TREAT FOR POSS FROSTBITE, THEN FLUSH W/PLENTY OF WATER.
AFTER INITIAL FLUSHING, REMOVE ANY CONTACT LENSES & CONTINUE
FLUSHING FOR AT LST 15 MINS. HAVE EYES EXAMINED & TESTED BY MED
PERS IF IRRIT DEVELOPS/PERSISTS. SKIN:TREAT FOR POSS FROSTBITE,
THEN WASH W/SOAP & WATER. REMOVE CONTAM CLTHG. GET MED ATTN IF
IRRIT DEVELOPS/PERSISTS. WASH CLTHG SEPARATELY BEFORE REUSE.
INGEST:TREAT FOR (SUPDAT)
Fire Fighting
Flash Point Method:TCC
Flash Point:NONE TO BOILING
Extinguishing Media:USE ALCOHOL FOAM, CARBON DIOXIDE OR WATER SPRAY
WHEN FIGHTING FIRES INVOLVING THIS MATERIAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONFLAMMABLE.
Accidental Release
Spill Release Procedures:LG SPILLS:SHUT OFF LEAK IF POSS & SAFE TO DO
SO. WEAR NIOSH APPRVD SCBA & APPROP PPE. ABSORB SPILL W/INERT MATL
(E.G., DRY SAND/EARTH), THEN PLACE IN CHEM WASTE CNTNR FOR PROPER
DISP. DO NOT FLUSH TO SEWER. AVOID RUNOFF INTO STORM SEWERS
&(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID PRLNG/RPTD CONTACT W/EYES, SKIN
& CLTHG. USE W/ADEQ VENT. AVOID BRTHG PRODUCT VAPOR OR MIST. DO NOT
REUSE THIS CNTNR. FOR INDUSTRIAL USE ONLY.
Other Precautions:STORE IN COOL, DRY PLACE AWAY FROM HEAT, SPKS &
FLAME. KEEP CNTNR CLSD WHEN NOT IN USE. DO NOT STORE IN DIRECT
SUNLIGHT. KEEP OUT OF REACH OF CHILDREN. PROD IS LEVEL 1 AEROSOL.
DO NOT PUNCTURE/INCIN C NTNRS. READ MSDS CAREFULLY PRIOR TO USE.
Exposure Controls
Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NORM VENT FOR STD MFG PRACTICES IS USUALLY ADEQ. GOOD GEN
VENT SHOULD BE SUFFICIENT TO CONTROL AIRBORNE LEVELS. (ING 6)
Protective Gloves:RUBBER/OTHER CHEMICALLY RESIST GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS BEFORE EATING.
Supplemental Safety and Health
FIRST AID PROC:POSS FROSTBITE. SWALLOWING <1 OZ WILL NOT CAUSE
SIGNIFICANT HARM. FOR LARGER AMTS, DO NOT INDUCE VOMIT. GET IMMED
MED ATTN. INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP.
IF B RTHG IS DFCLT, GIVE OXYGEN. GET MED ATTN. SPILL PROC:DITCHES
WHICH LEAD TO WATERWAYS. SM SPILLS:ABSORB SPILL W/ (ING 3)
Chemical Properties
Boiling Pt:B.P. Text:-16F,-27C
Vapor Pres:4730 @ 77F
Vapor Density:3.18
Spec Gravity:1.21 (H*2O=1)
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:67 MG/L @ 77F
Appearance and Odor:CLEAR, COLORLESS LIQUEFIED GAS; SLIGHT ETHEREAL
ODOR.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
DO NOT MIX W/POWDERED ALKALI & ALKALINE EARTH METALS OR STRONG
OXIDIZING AGENTS.
Stability Condition to Avoid:DO NOT SPRAY NEAR OPEN FLAMES, RED HOT
SURFACES OR OTHER SOURCES OF IGNITION.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY RELEASE
HYDROFLUORIC ACID VAPOR.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE & LOCAL
REGULATIONS. WATER RUNOFF CAN CAUSE ENVIRONMENTAL DAMAGE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.